Product ID:TWO PART POUR FOAM (2 LB DENSITY), 5614, PART B
MSDS Date:03/24/1995
FSC:9330
NIIN:00N080571
Kit Part:Y
MSDS Number: CFQTG

Responsible Party
FIBREGLASS-EVERCOAT CO INC
6600 CORNELL RD
CINCINNATI, OH 45242
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 513-489-7600

Cage: JO338

Contractor
FIBREGLASS-EVERCOAT CO INC
CINCINNATI, OH 45242 US

Telephone: 513-489-7600

Cage: JO338

Ingredients

ETHANE, 1,1-DICHLORO-1-FLUORO-; (HCFC-141B (DISPERSANT

CAS: 1717-00-6

RTECS: KI0997000

Fraction By Weight: 0-25%

OSHA PEL N/K

ACGIH TLV: N/K


AMINE; (AMINE MIXTURE)

Fraction By Weight: 0-25%

OSHA PEL N/K

ACGIH TLV: N/K


GLYCOLS

Fraction By Weight: 0-10%

OSHA PEL N/K

ACGIH TLV: N/K


HUMANS. ADRENOMIMETICS (I.E., EPINEPHRINE)

RTECS: 9999999ZZ


USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO

RTECS: 9999999ZZ


INTERNALLY. AVOID CONT W/EYES & SKIN. NO SMOKING

RTECS: 9999999ZZ


WELDING, OPEN FLAMES OR HOT SURFS. HEAT &/OR UV RADIA

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:CONT W/LIQ OR VAP MAY RSLT
IN IRRIT, REDNESS, TEARING & BLURRED VISION. SKIN:CONT W/WET MATL
MAY RSLT IN IRRIT, DERM. INHAL:EXCESSIVE INHAL OF VAPS MAY CAUSE
NASAL & RESP IRRIT, ACUTE NERV SYS DEPRESS, FATG, WEAK, NAUS, HDCH
& DIZZ. MAY CAUSE ALLERGIC RESP RXN IN SUSCEPTIBLE INDIVIDUALS.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INGEST:INGEST OF THIS MATL MAY CAUSE
GI IRRIT, NAUS, DIARR & VOMIT. ASPIR OF MATL INTO LUNGS DUE TO
VOMIT MAY PRDCE CHEM PNEUM WHICH CAN BE FATAL. CHRONIC:IRRIT TO
EYES & SKIN. CHLOROFLUOROCA RBON (CFC) MATLS HAVE PRDCD SENSIT OF
MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR EFT
IN (ING 4)
Medical Cond Aggravated by Exposure:THIS PRODUCT SHOULD NOT BE USED BY
PERSONS W/CHRONIC LUNG OR BREATHING PROBLEMS, OR BY INDIVIDUALS WHO
HAVE HAD PREVIOUS REACTION TO AMINES. PERSONS W/KNOWN ALLERGIES
SHOULD AVOID EXPOSURE TO PRODUCT.

First Aid

First Aid:EYES:FLUSH IMMEDIATELY W/LARGE AMOUNTS OF WATER FOR AT LEAST
15 MINUTES. SEE MD FOR MEDICAL TREATMENT. SKIN:IMMEDIATELY WASH
AFFECTED AREA W/SOAP & WATER. REMOVE CONTAM CLTHG. CONSULT MD IF
IRRIT DEVE LOPS. INHAL:REMOVE PERSON TO FRESH AIR.RESTORE BRTHG.
KEEP PERSON WARM & QUIET. TREAT SYMPTOMATICALLY. GET MED ATTN.
INGEST:KEEP PERSON WARM & QUIET. CONSULT MD OR POISON CONTROL
CENTER IMMEDIATELY.

Fire Fighting

Lower Limits:7.4%
Extinguishing Media:FOAM, CARBON DIOXIDE & DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED PRESSURE DEMAND SCBA & FULL
PROTECTIVE EQUIPMENT . FIREFIGHTERS MUST BE EQUIPPED TO PREVENT
VAPORS OR PRODUCTS OF COMBUSTION.
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODS MAY INCL FLUORIDES,
CHLORIDES & PHOSGENE. COMBUST. RAPID HEAT BUILD-UP CAN RUPTURE
DRUMS/CYLS. BURNING HCFC-141B CAN GENERATE(SUPDAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE
AREA. WEAR PROTECTIVE EQUIPMENT. AVOID BREATHING VAPORS. CONTAIN
SPILL. ABSORB SPILL W/INERT ABSORBENT. DISPOSE OF PROPERLY. WASH
SPILL AREA W/SOAP & WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE MATL IN COOL, WELL-VENTED AREA.
DO NOT STORE AT TEMPS >60-85F. DO NOT USE/STORE NEAR HEAT, SPARKS
OR OPEN FLAME. KEEP CNTNRS TIGHTLY CLOSED.
Other Precautions:AVOID CONT W/INCOMPAT MATLS. THIS PROD MUST BE MIXED
W/OTHER MATLS BEFORE USE. MIXT WILL HAVE HAZ PROPERTIES OF ALL
COMPONENTS. PLEASE REFER TO MSDS FOR EACH COMPONENT PRIOR TO USE.
KEEP OUT OF REACH OF CHILDREN. DO NOT TAKE (ING 6)

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATORS DESIGNED TO
REMOVE MISTS & ORGANIC SOLVENT VAPORS. IF PRODUCT IS TO BE SPRAYED,
NIOSH APPROVED RESPIRATORY PROTECTION IS REQUIRED.
Ventilation:GENERAL DILUTION OR LOCAL EXHAUST VENTILATION SHOULD BE
PROVIDED TO KEEP EXPOSURE BELOW ACCEPTABLE LIMITS.
Protective Gloves:NEOPRENE OR NATURAL RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
SHOWER . IMPERMEABLE CLTHG SHOULD BE WORN TO PVNT PRLNG/RPTD CONT
(SUPDAT)
Work Hygienic Practices:ALWAYS WASH HANDS AFTER USING THIS MATERIAL &
BEFORE EATING, DRINKING OR SMOKING.
Supplemental Safety and Health
EXPLO HAZ:HCL, HCF & PHOSGENE. HAZ DECOMP PROD:MONOXIDE, CARBON
DIOXIDE, OXIDES OF NITROGEN, POSSIBLY HYDROGEN CYANIDE, HCL, HCF &
POSSIBLY PHOSGENE. WASTE DISP METH:HAZ INFO IN OTHER SECTIONS OF
THIS MSDS. OTHER PROT EQUIP:OF WET MATL W/SKIN. BARRIER CREAM MAY
BE WORN FOR ADDITIONAL SKIN PROTECTION.

Chemical Properties

Boiling Pt:B.P. Text:90.0F,32.2C
Vapor Density:HVR/AIR
Spec Gravity:1.11
Evaporation Rate & Reference:SLOWER THAN ETHYL ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
WATER, MOISTURE, ALCOHOLS, AMINES, STRONG ACIDS & BASES.
Stability Condition to Avoid:HIGH TEMPERATURES, IGNITION SOURCES &
CONTACT W/INCOMPATIBLE MATERIALS.
Hazardous Decomposition Products:CHLORIDES, FLUORIDES . HAZ FUMES MAY
BE PRDCD WHEN MATL IS HEATED TO DECOMP. FUMES MAY CONTAIN CARBON
(SUPP DATA)

Disposal

Waste Disposal Methods:DISP OF I/A/W FED, STATE & LOC REGS. WASTE FROM
THIS PROD MAY BE HAZ AS DEFINED UNDER RCRA (40 CFR 261). WASTE MUST
BE TESTED FOR IGNITABILITY TO DETERMINE APPLIC EPA HAZ WASTE
NUMBERS. BEFORE ATTEMPT ING CLEAN-UP/DISPOSING OF MATL, REFER TO
(SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.